Technological Innovation

What is IEC 60601-1-2 Classification

In the field of medical electrical equipment, safety and reliability are of utmost importance. Compliance with international standards ensures that these devices meet certain criteria and can perform their intended function without posing unnecessary risk to patients and users. One such standard is the IEC 60601-1-2 classification, which specifies the basic safety and essential performance requirements for medical electrical equipment in the presence of electromagnetic disturbances.

The Purpose of IEC 60601-1-2

The main purpose of the IEC 60601-1-2 classification is to ensure that medical electrical equipment remains safe and effective when exposed to electromagnetic disturbances such as radio frequency (RF) fields, electrostatic discharge (ESD), and conducted or radiated transients. This standard helps manufacturers design equipment that can withstand these disturbances without impacting the device's performance or posing a risk to patients.

Classification Categories

The IEC 60601-1-2 standard classifies medical electrical equipment into three basic categories based on their ability to tolerate electromagnetic disturbances: Class A, Class B, and Class C.

Class A: Equipment classified as Class A is intended for use in professional healthcare facilities and has a lower level of immunity to electromagnetic disturbances. These devices must operate correctly in the presence of such disturbances, but temporary loss of function is allowed.

Class B: Equipment classified as Class B has a higher level of immunity compared to Class A devices. It is intended for use both in professional healthcare facilities and home healthcare environments. Class B devices must continue to function correctly during and after exposure to electromagnetic disturbances.

Class C: Equipment classified as Class C has the highest level of immunity to electromagnetic disturbances. These devices are specifically designed for life-supporting or critical care applications. Class C devices must have no loss of function during and after exposure to electromagnetic disturbances.

Compliance and Testing

Manufacturers are required to demonstrate compliance with the IEC 60601-1-2 standard for their medical electrical equipment. This typically involves testing the equipment in a controlled laboratory environment, subjecting it to various electromagnetic disturbances as specified in the standard. The equipment's performance is then evaluated to ensure it meets the necessary criteria for its classification category.

Compliance with IEC 60601-1-2 is essential for manufacturers to obtain regulatory approval and market their devices internationally. It provides assurance to healthcare professionals and patients that the equipment has undergone rigorous testing to ensure safety and reliability in the presence of electromagnetic disturbances.

CONTACT US

Contact: Eason Wang

Phone: +86-13751010017

E-mail: info@iec-equipment.com

Add: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China

Scan the qr codeclose
the qr code
TAGS Test Probe BTest Probe 18Test Probe 14Test Probe 17Test Probe 32Test Probe 1Test Probe 2Test Probe 12Test Probe 31Test Probe ATest Probe 41Test Probe 19Test Probe DTest Probe CTest Probe 13Test Probe 11Test Probe 43Test PinTest FingerTest Probe